Commercial morel growers should manage humidity, fogging, and CO2 as one linked system: fine fog adds moisture without soaking beds, fresh-air exchange keeps CO2 from climbing, and temperature control protects the balance. A single 80% RH target is not enough; the useful question is whether the room can hold its band while replacing stale air. In practice, that means monitoring three variables at once and adjusting the smallest input that fixes the drift.

Humidity and CO2 often move in opposite directions. Fogging raises relative humidity, but the same closed room lets respiration-driven CO2 accumulate; ventilating to lower CO2 can remove moisture and heat. This is why modern rooms separate the functions: a sensor-driven controller, a pulse-fogging system, and a ventilation strategy should be commissioned together. Sichuan Morel Research Institute’s 20FT and 40FT Edible Mushroom IoT Smart Cabins are specified for 4–28 °C (±0.5), 70–98% RH, and CO2 400–2000 ppm, with remote IoT monitoring, so growers can watch how one adjustment affects the other two.

Fog droplet size matters more than many new growers expect. Ultrasonic micro-fogging units produce droplets of 3–10 µm at 12–30 L/h. That fine mist is designed to evaporate into the air and raise RH, rather than fall as coarse spray that wets caps, substrate, and floors. Wet surfaces are a contamination and quality risk, so the aim should be humid air with dry surfaces, not visible water on the crop.

• Set the temperature band first. Keep it within the cabin or room’s rated range, and record the actual swing at canopy height, not only at the controller.

• Set RH as a band, not a fixed number. Use short fog pulses and let the controller confirm recovery before adding more water.

• Treat CO2 as an air-exchange signal. If CO2 climbs while RH is already high, fix ventilation before adding more fog.

• Check surfaces after each fog cycle. If caps or substrate stay wet for long periods, shorten pulses, improve air mixing, or reduce output.

Air movement is the hidden part of humidity control. Without gentle mixing, fine fog can stratify near the ceiling while the crop zone stays dry, or condense on cool surfaces. Use low-speed circulation that moves air through the canopy without blasting the beds. In cabins, place sensors where the crop actually lives; a wall-mounted sensor in a corner can read several points away from the real conditions. Filter fogging water, clean nozzles and tanks on schedule, and inspect drainage so spills do not become standing water. A high-humidity room is not a wet room: the target is stable 70–98% RH air within the equipment’s range, with no free water on floors, tools, or fruiting bodies.

For commercial scale, repeatability beats manual judgement. A room that can hold its temperature band, recover RH after a door opening, and keep CO2 within its working range gives staff a stable process to follow. That is also the logic behind the institute’s IoT cabins and climate controller equipment: compare trends, set alarms for drift, and adjust one variable at a time. More information is available at www.cn-localfoods.com.